Description
Specifications
Product Glance | Value |
Model | ANTRACK |
Version | V2 |
Capacity | 4 units ANTMINER (Hydro) or 4 units ANTMINER (U2 Hydro) or 2 units ANTMINER (U3 Hydro) |
Maximum load,kW | 24 |
Detailed Characteristics | Value |
Part 1: Mining Cabinet | |
Hardware Configuration | |
Size (Length*Width*Height), mm (without package) | 1200*600*1300 |
Size (Length*Width*Height), mm (with package) | 1460*1330*780 |
Net weight, kg (without package) | 130 |
Gross weight, kg (with package) | 185 |
Network connection mode | RJ45 Ethernet 10/100M |
Power Supply | |
Power supply AC Input voltage, Volt(1-1) | 380~415V AC |
Power supply AC Input Frequency Range, Hz | 50~60 |
Power supply AC Input current, Amp(1-2) | 63 |
Water pump | |
Rated power, W | 450 |
Noise, dBA@1m | 60 |
Lift, m | 19 |
Size (Length*Width* Height), mm | 360*210*268 |
Plate heat exchanger | |
Maximum heat exchange power, kW | 30 |
Size (Length*Width* Height), mm | 305*106*64 |
Diameter of water pipe connector, mm | DN20 |
Part 2: External Cooler(1-3) | |
Hardware Configuration | |
Size (Length*Width*Height), mm (without package) | 1160*1035*1570 |
Size (Length*Width*Height), mm (with package) | 1310*1185*1770 |
Net weight, kg (without package) | 380 |
Gross weight, kg (with package) | 432 |
Power supply | |
Power supply AC input voltage, Volt(1-1) | 380~415V AC |
Power supply AC input frequency range, Hz | 50~60 |
Maximum power supply AC input current, Amp(1-2) | 63 |
Heat pump | |
Heating Capacity (typical), kW | 32 |
Compressor Input (typical), kW | 8 |
EER (typical) | 3 |
Sound Level, Db(A) | 77 |
Refrigerant | R134a |
Heating water outlet temperature, °C | 80 |
Fan | |
Rated power, W | 1900 |
Noise, dBA@1m | 74 |
Size (Length*Height*Thickness), mm | 1010*1010*369 |
Water pump | |
Rated power, W | 370 |
Noise, dBA@1m | 74 |
Size (Length*Width* Height), mm | 328*205*461 |
Environment Requirements | |
Ambient temperature, °C | -20~40 |
Water flow, L/min | 32.0~40.0 (Cabinet side) |
Water pressure, bar | ≤3.5 |
Working fluid(1-4) | Antifreeze (10%) |
Installation distance, m(1-5) | 50 |
Liquid PH | 7.8~8.5 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Notes:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.
(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
(1-5) The distance between mining cabinet and external cooler.
Specification Details For U3S19 XP+H.
Product Glance | |
Model |
U3S19XP+H
|
Sub | 504T | 532T | 558T | 586T |
Version | 10 |
Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
Typical hashrate, TH/s(1-1) | 504T |532T |558T |586T |
Power on wall @35°C(1-2), Watt(1-1) | 9576 |10108 |10602 |10900 |
Power efficiency on wall @35°C(1-2), J/TH(1-1) | 19 |
Detailed Characteristics | |
Power Supply | |
Phase | 3 |
Input voltage, Volt(2-1) | 380~415 |
Input Frequency Range, Hz | 50~60 |
Input max current, Amp | 24 |
Power Port | LP34 |
Hardware Configuration | |
Networking connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm | 790*440*130 |
Server Size (Length*Width*Height, with package), mm | 997*637*252 |
Net weight, kg | 37 |
Gross weight, kg | 41 |
Environment Requirements | |
Inlet coolant temperature,°C | 20~50 |
Coolant flow, L/min | 16.0~20.0 |
Coolant pressure, bar | ≤3.5 |
Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
Coolant pH value | Antifreeze: 7.0~9.0
Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
Diameter of coolant pipe connector, mm | OD14 |
Storage temperature,°C | -20~70 |
Operation humidity(non-condensing) , RH | 10~90% |
NOTE:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual“, Chapter 9, Article 3, Point 6, “Maintenance of Coolant“!
| Purchasing Guidelines
NOTES
1. The ANTRACK is recommended to be used simultaneously with The hydro-cooling miners.
2. The pictures shown are for reference only; the final shipment version shall prevail.
3. Contact Customer Service Robot to review the shipping cost.
4. After an order has been submitted, a request to cancel the order, refund any part of the ordered amount or change the ordered item(s) to different item(s) or different batch(es) will not be entertained by hiveiris .
SHIPPING DETAILS
1. Shipments will be scheduled on a first-paid-first-ship basis for orders on which hiveiris has received full payment.
2. You are responsible for any customs delays or returned shipments due to a lack of proper documentation. It’s highly recommended to be aware of local customs clearance policies and prepare all customs documentation ahead of time to avoid delays or unexpected costs.
3. Click here to download Certificates of Conformity and find additional information on customs clearance for hiveiris products.
| Warranty
1. A 365-day warranty period is provided starting from the shipping date. hiveiris will cover shipping costs when shipping a replacement unit within the warranty period.
2. The warranty only applies to the original purchaser who purchased the machine directly from hiveiris . Once the miner is resold, warranty coverage becomes the responsibility of the re-seller.
3. If the user fails to use the product per the given instructions, specifications, and conditions provided or changes the function settings of the unit without hiveiris ‘s prior consent, hiveiris will not be liable for any damage arising therefrom.
4. Click here for a complete list of the Terms & Conditions that apply to all orders placed on https://hiveiris.com/